ORDINANCE NO. 9626

 

AN ORDINANCE OF THE CITY OF LAWRENCE, KANSAS, REPEALING EXISTING CHAPTER 5, ARTICLE 2 OF THE CODE OF THE CITY OF LAWRENCE, 2018 EDITION, AND AMENDMENTS THERETO, AND ENACTING, IN ITS PLACE, CHAPTER 5, ARTICLE 2 OF THE CODE OF THE CITY OF LAWRENCE, KANSAS, 2018 EDITION, AND AMENDMENTS THERETO, WHICH ADOPTS AND INCORPORATES BY REFERENCE THE 2018 INTERNATIONAL BUILDING CODE, REGULATING BUILDING AND CONSTRUCTION WITHIN THE CITY OF LAWRENCE, KANSAS.

 

BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF LAWRENCE, KANSAS:

 

SECTION 1. Existing Chapter 5, Article 2, of the Code of the City of Lawrence, Kansas, 2018 Edition, and amendments thereto, is hereby repealed in its entirety, it being the intent of the Governing Body that Section 2 of this Ordinance supersede it.

 

SECTION 2. The Code of the City of Lawrence, Kansas, 2018 Edition, and amendments thereto, is hereby amended by enacting Chapter 5, Article 2, which reads as follows:

 

ARTICLE 2.  BUILDING CODE

 

5-201               BUILDING CODE ADOPTED AND INCORPORATED.

The 2018 International Building Code, published by the International Code Council, Inc., other than those portions hereinafter specifically deleted, modified, or amended, is hereby adopted as the City's Building Code and is incorporated herein by reference as if set forth in full.

 

5-202               OFFICIAL COPY.

Not less than one (1) copy of the 2018 International Building Code shall be marked or stamped "OFFICIAL COPY AS INCORPORATED BY ORDINANCE No. 9626," with all sections or portions deleted, modified, or amended clearly marked as such, and to which one (1) copy of this ordinance shall be affixed, shall be filed with the City Clerk, shall be open to inspection, and shall be available to the public during reasonable business hours. Additional official copies shall, at the cost of the City, be supplied to those officials and agencies charged with enforcement of the City's Building Code.

 

5-203               AMENDMENTS TO THE 2018 INTERNATIONAL BUILDING CODE.

                        The 2018 International Building Code is amended as set forth in the succeeding sections of this Article. These amendments shall not serve to delete, modify, or amend any discretely numbered section or subsection of the 2018 International Building Code, unless the section or subsection is specifically identified as being deleted, modified, or amended.

 

5-204               Section 308.3.2 of the 2018 International Building Code is hereby amended to read as follows:

 

308.4.2 Five or fewer persons receiving medical care. A facility with five or fewer persons receiving medical care shall be classified as Group R-3 or shall comply with the 2018 International Residential Code, as adopted by the City, provided an automatic sprinkler system is installed in accordance with Section 903.3.1.3 or Section P2904 903.3.1.1 or 903.3.1.2 of the 2018 International Building Code, as adopted by the City.

 

5-205               Sections 310.4 and 310.4.1 of the 2018 International Building Code are hereby amended to read as follows:

 

310.4 Residential Group R-3. Residential Group R-3 occupancies where the occupants are primarily permanent in nature and not classified as Group R-1,        R-2, R-4 or I, and the occupancy equals or exceeds the occupancy limits established for that property at Section 20-601(d) of the City Code, as amended,  including:

 

Buildings that do not contain more than two dwelling units

Care facilities that provide accommodations for five or fewer persons receiving     care

Congregate living facilities (nontransient) with 16 or fewer occupants

 

            Boarding houses (nontransient)

            Convents

            Dormitories

            Fraternities and sororities

            Monasteries

 

Congregate living facilities (transient) with 10 or fewer occupants

 

            Boarding houses (transient)

 

Lodging houses (transient) with five or fewer guest rooms and 10 or fewer             occupants

 

310.4.1 Care facilities within a dwelling. Care facilities for five or fewer persons receiving care that are within a single-family dwelling are permitted to comply with the 2018 International Residential Code, as adopted by the City, provided an automatic sprinkler system is installed in accordance with Section 903.3.1.3 or within Section P2904 Section 903.3.1.2 of the 2018 International Building Code, as adopted by the City.

 

5-206               Sections 423.4 and 423.4.1 of the 2018 International Building Code are hereby to read as follows:

 

423.4 Group E occupancies. In areas where the shelter design wind speed for tornadoes is 250 MPH in accordance with Figure 304.2(1) of ICC 500, all new Group E occupancies with an occupant load of 50 or more shall have a storm shelter constructed in accordance with ICC 500.

 

 

 

Exceptions:

 

1.         Group E day care facilities.

 

2.         Group E occupancies accessory to places of religious worship.

 

3.         Buildings meeting the requirements for shelter design in ICC 500.

 

423.4.1 Required occupant capacity. The required occupant capacity of the storm shelter shall include all of the buildings on the site, and shall be greater than the following:

 

1.         The total occupant load of the classrooms, vocational rooms, and offices in the Group E occupancy.

 

2.         The occupant load or any indoor assembly space that is associated with the Group E occupancy.

 

Exceptions:

 

1.         Where a new building is being added on to an existing Group E site campus, and where the new building is not of sufficient size to accommodate the required occupant capacity of the storm shelter for all of the buildings on the site, the area of the new building does not increase the floor area of the classrooms, vocational rooms, and offices on the campus by more than 25%, the storm shelter shall at a minimum accommodate the required occupant capacity for the new building.

 

2.         Where approved by the code official, the required occupant capacity of the shelter shall be permitted to be reduced by the occupant capacity of any existing storm shelters on the site.

 

5-207               Section [F] 903.2.7 of the 2018 International Building Code is hereby amended to read as follows:

 

[F] 903.2.7 Group M. An automatic sprinkler system shall be provided throughout buildings containing a Group M occupancy where one of the following conditions exists:

 

1.         A Group M fire area exceeds 12,000 square feet (1115 ).

 

2.         A Group M fire area is located more than three stories above grade plane.

 

3.         The combined area of all Group M fire areas on all floors, including any mezzanines, exceeds 24,000 square feet (2230 ).

 

4.         A Group M occupancy used for the display and sale of upholstered furniture or mattresses exceeds 5,000 2,500 square feet               (464 232 m²).

5-208               Sections [F] 903.2.8, [F] 903.2.8.1, [F] 903.2.8.2, [F] 903.2.8.3, [F] 903.2.8.3.1, [F] 903.2.8.3.2, and [F] 903.2.8.4 of the 2018 International Building Code are hereby amended to read as follows:

 

[F] 903.2.8 Group R. An automatic sprinkler system installed in accordance with Section 903.3 shall be provided throughout all buildings with a Group R fire area.

 

            Exception: An automatic sprinkler system is not required in Group R-3 occupancies that contain less than three dwelling units. However, an automatic sprinkler system shall be provided in all Group R-3 boarding houses, care facilities, congregate living facilities, and lodging houses, regardless of the number of dwelling units.

 

            [F] 903.2.8.1 Group R-3. An automatic sprinkler system in accordance with Section 903.3.1 903.3.1.2 shall be permitted in Group R-3 occupancies.

 

            [F] 903.2.8.2 Group R-4 Condition 1. An automatic sprinkler system in accordance with Section 903.3.1 903.3.1.2 shall be permitted in Group R-4 Condition 1 occupancies.

 

            [F] 903.2.8.3 Group R-4 Condition 2. An automatic sprinkler system in accordance with Section 903.3.1.2 shall be permitted in Group R-4 Condition 2 occupancies. Attics shall be protected in accordance with Section 903.2.8.3.1 or 903.2.8.3.2.

 

            [F] 903.2.8.3.1 Attics used for living purposes, storage or fuel-fired equipment. Attics used for living purposes, storage or fuel-fired equipment shall be protected throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.2.

 

            [F] 903.2.8.3.2 Attics not used for living purposes, storage or fuel-fired equipment. Attics not used for living purposes, storage or fuel-fired equipment shall be protected in accordance with one of the following:

 

1.         Attics protected through by a heat detector system arranged to activate the building fire alarm system in accordance with Section 907.2.11.

 

2.         Attics constructed of noncombustible materials.

 

3.         Attics constructed of fire-retardant-treated wood framing complying with Section 2303.2.

 

4.         The automatic sprinkler system shall be extended to provide protection throughout the attic space.

 

[F] 903.2.8.4 Care facilities. An automatic sprinkler system installed in accordance with Section 903.3.1.3 903.3.1.2 of the 2018 International Building Code, as adopted by the City, shall be permitted in care facilities with five or fewer individuals in a single-family dwelling.

 

5-209               Section [F] 903.3.1.3 of the 2018 International Building Code is hereby amended to read as follows:

           

903.3.1.3 NFPA 13D sprinkler systems. Automatic sprinkler systems installed in one- and two-family dwellings; Group R-3, Group R-4 Condition 1 and townhouses shall be permitted to be installed throughout in accordance with NFPA 13D.

 

5-210               Table 1004.1.2, "Maximum Floor Area Allowances Per Occupant," of the 2018 International Building Code is hereby amended to read as follows:

 

TABLE 1004.1.2

MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT

 

          FUNCTION OF SPACE

OCCUPANT LOAD FACTORa

Accessory storage areas, mechanical equipment room

300 gross

Agricultural building

300 gross

Aircraft hangars

500 gross

Airport Terminal

    Baggage claim

    Baggage handling

    Concourse

    Waiting areas

 

20 gross

300 gross

100 gross

15 gross

Assembly

    Gaming floors (keno, slots, etc.)

    Exhibit Gallery and Museum

 

11 gross

30 net

Assembly with fixed seats

See Section 1004.4

Assembly without fixed seats

   Concentrated (chairs only-not fixed)

   Standing space

   Unconcentrated (tables and chairs)

 

7 net

5 net

15 net

Bowling centers, allow 5 persons for each lane including 15 feet of runway, and for additional areas

 

7 net

Business areas

      Concentrated business use areas

150 gross

See Section 1004.8

Courtrooms—other than fixed seating areas

40 net

Day care

35 net

Dormitories

Sleeping Dormitories

 

50 gross

25 gross

Educational

    Classroom area

    Shops and other vocational room areas       

 

 

20 net

50 net

 

Exercise rooms

50 gross

Group H-5 Fabrication and manufacturing areas

200 gross

Industrial areas

100 gross

Institutional areas

     Inpatient treatment areas

     Outpatient areas

     Sleeping areas

 

240 gross

100 gross

120 gross

Kitchens, commercial

200 gross

Library

   Reading rooms

   Stack area

50 net

100 gross

Mall buildings—covered and open

See Section 402.8.2

Mercantile

Storage, stock, shipping areas

 

300 gross

 

Parking garages

200 gross

Residential

200 gross

Skating rinks, swimming pools

Rink and pool

Decks

 

50 gross

15 gross

Stages and platforms

15 net

Warehouses

500 gross

For SI: 1 square foot = 0.0929 .

a Floor area in square feet per occupant.

 

SECTION 3. If any section, sentence, clause, or phrase of this ordinance is found to be unconstitutional or is otherwise held invalid by any court of competent jurisdiction, it shall not affect the validity of any remaining parts of this ordinance. 

 

SECTION 4. After passage and publication as provided by law, this ordinance shall be in full force and effect commencing July 1, 2019.

 

PASSED by the Governing Body of the City of Lawrence, Kansas, this ____ day of __________, 2019.

 

 APPROVED:

 

 

 

___________________________________

Lisa Larsen

Mayor

ATTEST:

 

 

 

__________________________________

Sherri Riedemann

City Clerk

 

APPROVED AS TO FORM:  

 

                 

 

__________________________________

Toni R. Wheeler

City Attorney